Pattern Operation (cont’d)

NOTES : – When Function Code 65 is set

to 1, 2 or 3, pattern operation is made
possible by setting the multi-step
frequency combination of stages 1 through 7
(Function Codes 66 through 72).

– When in the pattern operation,
frequency changeover via the X1, X2 and X3
terminals is not required.

– Pattern operation switches to set
frequencies 1 through 7 in ascending numerical
order only.

– To set motor’s direction of
rotation and acceleration/deceleration time,
utilize Function Codes 66 through 72.

– If each subsequent frequency is
higher or lower than the present frequency, the
acceleration or deceleration time will be auto-
matically selected based on the Stage setting
(Function Codes 66 through 72).