Logic Functions - Book 1

DIGITAL OUTPUT MODULE BLOCKS (DOM, DDOM, WDOM)

5-22

DOM 20

Track Status Quality (TRKQ)............................................................................................– WR

DDOM 23

Track Status Quality (TRKQ1)..........................................................................................– WR

DDOM 33

Track Status Quality (TRKQ2)..........................................................................................– WR

WDOM 20

Track Status Quality (TRKQ)............................................................................................– WR
This data quality field is not changed by any internal logic and will always be GOOD unless
written otherwise.

DOM 21

Initial Scaled Result Value (RSC) .................................................................................... CWR

DDOM 24

Initial Scaled Result Value (RSC1) .................................................................................. CWR

DDOM 34

Initial Scaled Result Value (RSC2) .................................................................................. CWR

WDOM 21

Initial Scaled Result Value (RSC) .................................................................................... CWR
This is the scaled result of the block evaluation. The result is writeable when the block is in
manual, the I/O locked, or the instrument state is not run (as during download of the
configuration, which establishes the initial result value). Any write to the scaled result will
cause the result quality to be set GOOD.

FALSE

0

Result before action is applied is open.

TRUE

1

Result before action is applied is closed.

DOM 22

Scaled Readback (RB) ...................................................................................................... – – R

DDOM 25

Scaled Readback (RB1) .................................................................................................... – – R

DDOM 35

Scaled Readback (RB2) .................................................................................................... – – R

WDOM 22

Scaled Readback (RB) ...................................................................................................... – – R
The value sent to the output module is read back from the select circuit every base scan cycle,
action is applied, and the value is stored as the scaled readback value.

DOM 23

Input (INPUT) ..................................................................................................................... CWR

DDOM 36

Input 1 (INPUT1) ................................................................................................................ CWR

DDOM 37

Input 2 (INPUT2) ................................................................................................................ CWR

WDOM 23

Input (INPUT) ..................................................................................................................... CWR
This is the input to the block used to determine the output. The input can be local data or a
logical source pointer. When the input is local data, it can be written.

FALSE

0

Local input value is low.

TRUE

1

Local input value is high.

LSP

Local input is a discrete logical source pointer.

DOM 24

Readback (RB)................................................................................................................... – – R

DDOM 38

Readback (RB1)................................................................................................................. – – R

DDOM 42

Readback (RB2)................................................................................................................. – – R

WDOM 24

Readback (RB)................................................................................................................... – – R
The value sent to the output module is read back from the select circuit every base scan cycle
and the value is stored as the readback value.

DOM 25

Readback Quality (RBQ)................................................................................................... – – R

DDOM 39

Readback Quality (RBQ1)................................................................................................. – – R

DDOM 43

Readback Quality (RBQ2)................................................................................................. – – R

WDOM 25

Readback Quality (RBQ)................................................................................................... – – R
Readback quality is set BAD if a digital output module error occurs.