Logic Functions - Book 1

ANALOG INPUT BLOCKS (VCI, TII, TI, RI, RTI, RTTI)

7-26

TTI 16

Transmitter Range - Bottom (TRANSLO) ........................................................................ CWR

RTTI 16

Transmitter Range - Bottom (TRANSLO) ........................................................................ CWR
Transmitter bottom of range for TTI and RTTI blocks. Specified in result units as described for
Top of Range.

TTI 17

Output Calibrate - Zero (ZERO) ....................................................................................... CWR

TI 14

Output Calibrate - Zero (ZERO) ....................................................................................... CWR

RTI 14

Output Calibrate - Zero (ZERO) ....................................................................................... CWR

RTTI 17

Output Calibrate - Zero (ZERO) ....................................................................................... CWR
Zero calibration value for TTI, TI, RTI, and RTTI blocks. Specified in result units.

TTI 18

Output Calibrate - Span (SPAN)....................................................................................... CWR

TI 15

Output Calibrate - Span (SPAN)....................................................................................... CWR

RTI 15

Output Calibrate - Span (SPAN)....................................................................................... CWR

RTTI 18

Output Calibrate - Span (SPAN)....................................................................................... CWR
Span calibration value for TTI, TI, RTI, and RTTI blocks. Multiplier with 1.0 nominal.

VCI 17

Quality Limit - Top (QUALHI)............................................................................................ CWR

TTI 19

Quality Limit - Top (QUALHI)............................................................................................ CWR

TI 16

Quality Limit - Top (QUALHI)............................................................................................ CWR

RI 16

Quality Limit - Top (QUALHI)............................................................................................ CWR

RTI 16

Quality Limit - Top (QUALHI)............................................................................................ CWR

RTTI 19

Quality Limit - Top (QUALHI)............................................................................................ CWR
Sets result quality BAD if result exceeds this engineering units value. The top quality limit
must be greater than or equal to the bottom quality limit.

VCI 18

Quality Limit - Bottom (QUALLO) .................................................................................... CWR

TTI 20

Quality Limit - Bottom (QUALLO) .................................................................................... CWR

TI 17

Quality Limit - Bottom (QUALLO) .................................................................................... CWR

RI 17

Quality Limit - Bottom (QUALLO) .................................................................................... CWR

RTI 17

Quality Limit - Bottom (QUALLO) .................................................................................... CWR

RTTI 20

Quality Limit - Bottom (QUALLO) .................................................................................... CWR
Sets result quality BAD if result is less than this engineering units value. The bottom quality
limit must be less than or equal to the top quality limit.

VCI 19

Initial Value (Result) (R).................................................................................................... CWR

TTI 21

Initial Value (Result) (R).................................................................................................... CWR

TI 18

Initial Value (Result) (R).................................................................................................... CWR

RI 18

Initial Value (Result) (R).................................................................................................... CWR

RTI 18

Initial Value (Result) (R).................................................................................................... CWR

RTTI 21

Initial Value (Result) (R).................................................................................................... CWR
This is the output of the input block. This output is the result of an input module producing a
digital count of the analog signal and the input block filtering, normalizing, linearizing, and
converting the input count value to an engineering units value for VCI and RI blocks or to a
temperature value in the specified Temperature Scale units for TTI, TI, RTI, and RTTI blocks.