Baud rate change, Safety velocity – IAI America SEL-TG User Manual

Page 233

Advertising
background image

16. Controller

215

18

.7.

Baud Rate Change

Changes the communication baud rate between the controller and the teaching pendant.

Select the F2 (Baud) key on the controller item screen.

Mode Transition:

Input values corresponding to the baud rate by using
the 10 keys and press the return key.
0: 9.6 2: 38.4 5: 115.2 [kbps]
To change the baud rate, press the F1 (OK) key.
To cancel, press F2 (Canc) key. It returns to the
previous screen.

'XULQJEDXGUDWHFKDQJH³3OHDVHZDLW³EOLQNV

Return to the baud rate change screen.

18

.8. Safety

Velocity

Switches the safety velocity limit status at manual mode.

Select the F2 (SVel) key on the controller item screen.

Mode Transition:

Input 1 or 0 by using the 10 keys and press the
return key.
1: Safety Velocity Limit Effect

In the case of the orthogonal axis, the maximum
velocity is under 250 mm/sec. The setting of the
programs and parameters do not affect it. In the
case of the SCARA axis, the maximum velocity is
 PPVHF RU ORZHU IRU &3 PRWLRQ DQG  RU
OHVVIRU373PRWLRQ

0: Safety Velocity Limit does not Effect

To switch the safety velocity limit status, press the

F1 (OK) key.

To cancel, press the F2 (Canc) key.

16.7.

16.8.

Advertising
This manual is related to the following products: