5. How to Save Data

24

5.2. Set-up at Shipment without System Memory Backup Battery (Table Top

Actuator (TT), SSEL, ASEL, PSEL)

2WKHUSDUDPHWHU1R  6\VWHPPHPRU\EDFNXSEDWWHU\XQHTXLSSHG

Edit data with PC or

Teaching Pendant

Save the data during the

power is on and delete

the data by reset

Save data even after the power OFF

Program

Parameter

(content 1)

Symbol

Position

Slave card

parameter

(content 2)

Transmit

Transmit

Transmit

Transmit

* Encoder

parameter

SEL global data

(content 3)

Error list

Memory

Memory

Memory

Flash write

Reset read

Transmit

Reset read

Transfer

Reset read

Flash

memory

* Encoder

Memory

Since the program, parameter, symbol, and position will be read from flash memory at restart

time, the data in memory becomes the original data before editing unless the data is written in

ÀDVKPHPRU\

The controller always operates according to the data in memory (within the dotted box) excluding

parameters.

1RWH6(/JOREDOGDWDFDQ¶WEHVDYHGZLWKRXWWKHEDFNXSEDWWHU\