* Supplement

280

* Supplement

Orthogonal Axis Synchro Specification Absolute Reset
: X-SEL-K, P/Q, 5 axis and 6 axis of PX/QX, TT, SSEL, ASEL and PSEL
controller

The following are descriptions about the absolute reset methods for synchro specification axes.

The products ordered as the synchro specification are shipped after setting parameters to the

synchro specification. However, change the parameters when executing an absolute reset.

1. Synchro Axes

Synchro axes are comprised of the master axis (main axis) and the slave axis (sub-axis). The

axis of which the number is smaller becomes the master axis.

Program commands are valid only for the master axis. (Commands to the slave axis are

prohibited.)

As the absolute reset methods, there is the standard procedure and the special procedure. Which

procedure to be used is determi

QHGE\WKH³HDFKD[LVSDUDPHWHU1RHQFRGHU$%6,1&W\SH´

values for the master and slave axes.

³(DFK$[LV3DUDPHWHU1R(QFRGHU$%6,1&7\SH´9DOXHV

Master Axis

Slave Axis

Absolute Reset Methods

1 1

Special procedure

1 0

Standard procedure

0 0

(When the value is 0 for both the master axis and the slave axis, both the axes are of the

increment specification.)

([DPSOH :KHQVSHFLDOSURFHGXUHLV executed for 2-axis controller:
Mode Transition:

Note: To change the axis No., use the F3 (Dev-) key or F4 (Dev+) key.

([DPSOH :KHQVWDQGDUGSURFHGXUHLV executed for 2-axis controller:

Master axis with a smaller axis No.

Slave axis

: 5th and 6th Axes of XSEL-K, P/Q, or PX/QX Controller, 5th to 8th Axes

of R/S or RX/SX Controller, or TT, SSEL, ASEL or PSEL Controller