IAI America SEL-TG User Manual

Page 37

Advertising
background image

19


7HDFKLQJ3HQGDQW)XQFWLRQDQG6SHFL¿FDWLRQV

19

13. MOVE key

Enables actuator movement or continuous operation. The LED of MOVE is lit. (It is valid in

the Teac (teach) mode area.)

When you press a jog key such as 1+ and 1- after enabling movement or continuous

operation, movement action starts. However, it is required to switch servo ON when the

servo is OFF.

Jog operation is made possible after the action has been completed or stopped. The LED of

JOG is lit up.

14. STOP key

Stops actuator movement or continuous movement. (It is valid in the Teac (teach) mode area

with the servo ON.)

15. SERVO key

Enables axis servo ON/OFF switching operation. The LED of SERVO is lit up. (It is valid in

the Teac (teach) mode area.)

When you press a + jog key such as 1+ after enabling servo ON/OFF switching operation,

the servo is turned ON. When you press a - jog key such as 1-, the servo is turned OFF.

Jog operation is made possible after the servo has been turned ON/OFF. The LED of JOG is

lit. However, when the servo is OFF, the actuator cannot be moved by jog or inching

operation unless the servo is turned ON.

16. HOME key

Enables homing operation. The LED of HOME is lit. (It is valid in the Teac (teach) mode

area.)

When you press a jog key such as 1+ and 1- after enabling homing operation, homing starts.

However, it is required to turn the servo ON when the servo is OFF.

Jog operation is made possible after homing has been completed. The LED of JOG is lit.

17.

1- 1+

2- 2+ 3- 3+

4- 4+

ALL-

and

ALL+

(Jog keys)

1-

Minus direction jog movement for the 1st axis and 5th axis

1+

Plus direction jog movement for the 1st axis and 5th axis

2-

Minus direction jog movement for the 2nd axis and 6th axis

2+

Plus direction jog movement for the 2nd axis and 6th axis

3-

Minus direction jog movement for the 3rd axis

3+

Plus direction jog movement for the 3rd axis

4-

Minus direction jog movement for the 4th axis

4+

Plus direction jog movement for the 4th axis

ALL-

Minus direction jog movement for all axes

ALL+

Plus direction jog movement for all axes

(It is valid in the Teac (teach)
mode area with the servo
ON

For the Linear Servo actuator, LSAS-N10/N15 quasi absolute type, the actuator
moves in a range of approximately 16mm from the stop position when a home
return operation is conducted after the power is turned on to confirm the current
position. Watch the actuator movement during operation.