16. Controller

240

For absolute reset for the ZR unit, a series of operations of the vertical axis and rotation axis is
performed. Because there is an item for operating the robot in the adjustment procedure, perform
the adjustment in the condition where the actuator is available by setting the appropriate moving
range of the actuator and arranging it so there are no obstacles etc. for the actuator.

Select the F1 (RAbs) key on the controller item screen.

Mode flow:

When performing an absolute reset, press the F1 (Yes)
key.
When not performing an absolute reset, press the

F2 (No) key. The display returns to the previous

screen.

Axis No. input

Input the vertical axis No. for the ZR unit using the
ten-key pad and press the return key.

When continuing an absolut e reset, press the F1 (OK)
key.
When canceling an absolute reset, press the F2 (Canc)
key.
When canceling an absolute reset on any screen of
the following

㽲 through 㾀, press the F2 (Canc) key.

Encoder multi-rotation data reset (1)

Press the F1 (OK) key.

Controller error reset

Press the F1 (OK) key.

[2]

Absolute Reset Procedures

Ctl

RAbs

-