46

Brocade FastIron GS and GS-STK Hardware Installation Guide

53-1002186-02

Upgrading hardware

4

DRAFT: BROCADE CONFIDENTIAL

Upgrading hardware

You need a Phillips-head screwdriver and an ESD wrist strap to perform this procedure. You also
need a static-free work area.

To perform the upgrade:

1. Remove all power cables from the device.

2. Remove the device from the equipment rack, if necessary, and place the device in a static-free

work area.

3. Put on the supplied ESD wrist strap and attach the clip end to a metal surface (such as an

equipment rack) to act as ground.

4. Disassemble the device as follows (refer to

Figure 38

on page 47):

Use a Phillips-head screwdriver to remove the two screws in the bottom corners of each
side. If rack mounting ears are installed, remove the four screws that hold each ear to the
device. Refer to

Figure 38

.

Turn the device so that the front (where the port connectors are) is facing you.

Slide the cover backwards to free the lip edge of the cover from the front plate. Make sure
the cover is completely free of the front panel.

.5 meter CX4 cable

Upgrade label

Upgrade label

TABLE 8

Upgrade kit contents (Continued)

Kit with CX4 Module:
FGS624-STK-CXU, FGS648-STK-CXU,

Kit without CX4 Module:
FGS624-STK-U, FGS648-STK-U

WARNING

Disconnect the power cord from all power sources to completely remove power from the
device.

ACHTUNG

Ziehen Sie das Stromkabel aus allen Stromquellen, um sicherzustellen, dass dem Gerät
kein Strom zugeführt wird.

AVERTISSEMENT

Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour couper
complètement l'alimentation du dispositif.

ADVERTENCIA

Para desconectar completamente la corriente del instrumento, desconecte el cordón de
corriente de todas las fuentes de corriente.