Brocade FastIron GS and GS-STK Hardware Installation Guide

53-1002186-02

Replacing a power supply

8

DRAFT: BROCADE CONFIDENTIAL

Installation precautions and warnings

Follow these precautions when installing a power supply in the FGS and FGS-STK device.

DANGER

Before beginning the installation, refer to the precautions in

“Power precautions”

on page 20.

Do not install the device in an environment where the operating ambient temperature might exceed
40 Deg. Celsius C (104 Deg. F).

CAUTION

Never leave tools inside the device.

Determining which power supply failed

If you are replacing a power supply that has failed and you are not sure which supply has failed,
enter the following command at any CLI command prompt:

This command displays status information for the power supplies and the fans. The power supplies
are numbered from left to right. These numbers assume you are facing the front of the device, not
the rear.

If the display indicates “Installed (Failed)” for any of the slots, the power supply installed in that
particular slot has failed.

AC power supplies

If you need to install or replace an AC power supply, refer to the procedures on

“Installing an AC

power supply”

on page 24.

DC power supplies

if you need to install or replace a DC power supply, refer to

“Installing a DC power supply”

on

page 26.

FastIron>show chassis

power supply 1 <NA - AC - Regular> present, status ok

power supply 2 not present

Fan 1 ok

Fan 2 ok

Exhaust Side Temperature Readings:

Current temperature : 28.5 degrees Celsius

Warning level.......: 45.0 degrees Celsius

Shutdown level......: 55.0 degrees Celsius

Intake Side Temperature Readings:

Current temperature : 29.0 degrees Celsius

Boot Prom MAC: 00e0.5200.0100