6

DRAFT: BROCADE CONFIDENTIAL

Environmental considerations

For optimal performance, operate or store your Brocade FGS or FGS-STK device in compliance with
the following environmental conditions.

Cooling

FGS or FGS-STK devices have two single-speed fans that operate simultaneously to cool the CPU,
main memory, and voltage regulators. If one fan fails, it does not affect the operation of the other
fan. The fans use either a push or pull configuration to move the air from the left side of the device
to the right side of the device as shown in

Figure 47

FIGURE 47

Device air flow

2

TABLE 13

Environmental Conditions for the Device

Description

Range

Operating Environment

Operating temperature

32



– 104

F (0

– 40

C)

Operating altitude

6,600 feet maximum

Relative humidity

5 to 95%, @ 104

F (40

C), non-condensing

or
5 to 95% non-condensing for DC power supply

Operating noise

47 – 51 dB

Maximum heat
dissipation

328 BTU/Hr with 2-port 10-Gigabit uplinks
280 BTU/Hr without 2-port 10-Gigabit uplinks

Storage Environment

Storage temperature

-23

to 158



F, -25

to 70

C

Storage humidity

95% maximum, non-condensing

Storage altitude

15,000 feet ( 3,000 meter) maximum

1