Mean time between failure, Power draw specifications, Draft: brocade confidential – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual

Page 80

Advertising
background image

70

Brocade FastIron GS and GS-STK Hardware Installation Guide

53-1002186-02

Device specifications

6

DRAFT: BROCADE CONFIDENTIAL

Mean Time Between Failure

Table 16

lists the Mean Time Between Failure (MTBF) for the FastIron GS, FastIron GS-STK, and 10

Gbps uplink modules. The MTBF is the average estimated time, in hours, before a hardware failure
may occur.

Power draw specifications

Table 17

lists the typical and maximum power draw specifications for FGS and FGS-STK models.

TABLE 15

Device Power Surge and Drop Protection

Property

Protection Mechanism

Power surge

MOV and Spark Gap protection

Power drop (<=1 second)

An AC loss of >15ms will cause the power supply to shut
down due to input under-voltage

Maximum power draw

96 watts with 2-port 10-Gigabit uplinks
82 watts without 2-port 10-Gigabit uplinks

TABLE 16

MTBF for the FastIron GS and GS-STK and 10 Gbps Modules

Configuration/Module

Temperature

MTBF (hours)

Without POE

With POE

24-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 1 power supply

40 Deg. Celsius

150,879

142,217

24-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 2 powers supplies

40 Deg. Celsius

267,411

241,356

48-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 1 power supply

40 Deg. Celsius

133,825

120,775

48-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 2 power supplies

40 Deg. Celsius

218,140

196,401

2-port 10 Gbps XFP module

40 Deg. Celsius

1,597,580

N/A

2-port 10 Gbps CX4 module

40 Deg. Celsius

N/A

29,673,590

1-port 10 Gbps XFP + 1-port 10 Gbps CX4 module

40 Deg. Celsius

N/A

2,364,614

1-port 10 Gbps XFP module

40 Deg. Celsius

N/A

2,501,219

Advertising