Troubleshooting network connections

5

DRAFT: BROCADE CONFIDENTIAL

Viewing the results of the cable analysis

To display the results of the cable analysis, enter a command such as the following at the Privileged
EXEC level of the CLI:

Syntax: show cable-diag tdr <port-num>

Table 11

defines the fields shown in the command output.

Digital Optical Monitoring

NOTE

Digital Optical Monitoring is not supported for FGS-STK devices running release 05.0.01.

You can configure your Foundry device to monitor optical transceivers in the system, either globally
or by specified port. When this feature is enabled, the system monitors the temperature and signal
power levels for the optical transceivers in the specified ports. Console messages and syslog
messages are sent when optical operating conditions fall below or rise above the XFP or SFP
manufacturer’s recommended thresholds. For more information about digital optical monitoring,
refer to the FastIron Configuration Guide.

TABLE 11

Cable Statistics

This Line...

Displays...

Port

The port that was tested.

Speed

The port’s current line speed.

Local pair

The local link name.

Pair Length

The cable length when terminated, or the distance to the point of fault when
the line is not up.

Remote pair

The remote link name.

Pair status

The status of the link. This field displays one of the following:

Terminated: The link is up.

Shorted: A short is detected in the cable.

Open: An opening is detected in the cable.

ImpedMis: The impedance is mismatched.

Failed: The TDR test failed.

FGS 624#show cable-diag tdr 1

Port Speed Local pair Pair Length Remote pair Pair status

--------- ----- ---------- ----------- ----------- -----------

01 1000M Pair A <50M Pair B Terminated

Pair B <50M Pair A Terminated

Pair C <50M Pair D Terminated

Pair D <50M Pair C Terminated