Using virtual cable testing to diagnose a cable, Command syntax – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual

Page 75

Advertising
background image

Brocade FastIron GS and GS-STK Hardware Installation Guide

65

53-1002186-02

Troubleshooting network connections

5

DRAFT: BROCADE CONFIDENTIAL

Verify that the Brocade device and the connected device are both powered on and operating
correctly.

Verify that you have used the correct cable type for the connection:

For twisted-pair connections to an end node, use straight-through cabling.

For fiber-optic connections, verify that the transmit port on the device is connected to the
receive port on the connected device, and that the receive port on the device is connected
to the transmit port on the connected device.

Verify that the port has not been disabled through a configuration change. You can use the
CLI. If you have configured an IP address on the device, you also can use the Web
management interface or IronView Network Manager.

For copper ports, you can test the cable using Virtual Cable Testing. Refer to

“Using Virtual

Cable Testing to diagnose a cable”

.

If the other procedures do not resolve the problem, try using a different port or a different
cable.

Using Virtual Cable Testing to diagnose a cable

NOTE

Virtual Cable Testing is not supported for FGS-STK devices running software version 05.0.01.

FGS devices support Virtual Cable Test (VCT) technology. VCT technology enables you to diagnose a
conductor (wire or cable) by sending a pulsed signal into the conductor, then examining the
reflection of that pulse. This method of cable analysis is referred to as Time Domain Reflectometry
(TDR). By examining the reflection, the Brocade device can detect and report cable statistics such
as local and remote link pair, cable length, and link status.

Configuration notes

This feature is supported on copper ports only. It is not supported on fiber ports.

The port to which the cable is connected must be enabled when you issue the command to
diagnose the cable. If the port is disabled, the command is rejected.

If the port is operating at 100 Mbps half-duplex, the TDR test on one pair will fail.

If the remote pair is set to forced 100 Mbps, any change in MDI or MDIX may cause the device
to interpret the Multilevel Threshold-3 (MLT-3) as a reflected pulse, in which case, the device
will report a faulty condition. In this case, Brocade recommends that you run the TDR test a
few times for accurate results.

Command syntax

To diagnose a cable using TDR, enter a command such as the following at the Privileged EXEC level
of the CLI:

FGS 624# phy cable-diag tdr 1

This command diagnoses the cable attached to port 1.

Syntax: phy cable-diag tdr <port-num>