Displaying temperature messages, Draft: brocade confidential – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual

Page 94

Advertising
background image

84

Brocade FastIron GS and GS-STK Hardware Installation Guide

53-1002186-02

Managing temperature settings

7

DRAFT: BROCADE CONFIDENTIAL

The following output is for an IronStack:

Displaying temperature messages

The software sends a Syslog message and an SNMP trap if the temperature crosses the warning
threshold. The following methods describe how to view the system log on the device. If you have
configured the device to use a Syslog server or SNMP trap receiver, refer to the documentation for
the server or receiver.

To display the system log, enter the following command at any CLI level. The following example is for
a standalone device. To display system logs for IronStack devices, enter the show log command for
individual stack units.

FastIron>show chassis

power supply 1 <NA - AC - Regular> present, status ok

power supply 2 not present

Fan 1 ok

Fan 2 ok

Exhaust Side Temperature Readings:

Current temperature : 28.5 degrees Celsius

Warning level.......: 45.0 degrees Celsius

Shutdown level......: 55.0 degrees Celsius

Intake Side Temperature Readings:

Current temperature : 29.0 degrees Celsius

Boot Prom MAC: 00e0.5200.0100

FGS648P Switch#show chassis

The stack unit 1 chassis info:

Power supply 1 (NA - AC - Regular) present, status ok

Power supply 2 not present

Fan 1 ok

Fan 2 ok

Exhaust Side Temperature Readings:

Current temperature : 35.5 deg-C

Warning level.......: 80.0 deg-C

Shutdown level......: 90.0 deg-C

Intake Side Temperature Readings:

Current temperature : 33.5 deg-C

Boot Prom MAC: 0012.f2de.9440

Management MAC: 0000.0000.0011

The stack unit 2 chassis info:

Power supply 1 (NA - AC - Regular) present, status ok

Power supply 2 not present

Fan 1 ok

Fan 2 ok

--More--, next page: Space, next line: Return key, quit: Control-c