Environmental considerations

For optimal performance, operate or store the power supplies in compliance with the following
environmental conditions.

Power supply consumption

Table 21

lists the maximum power supply consumption for each FastIron GS model.

Table 22

lists the maximum power supply consumption for each FastIron GS-STK model.

TABLE 20

Power Supply Operating and Storage Environment

Description

Range

Operating Environment

Operating temperature

32

– 104

F (0

– 40

C)

Relative humidity

0 – 95%, non-condensing

Operating altitude

Up to 10,000 feet above sea level

Operating noise

47 – 51 dBA

Cooling

AC: internal fans, 50mm

DC: internal fan, 60 mm

Storage Environment

Storage temperature

-40

to 185

F, -40

to 85

C

Storage humidity

95% maximum, non-condensing

Storage altitude

Up to 15,000 feet above sea level

TABLE 21

Maximum Power Supply Consumption for FGS Models

Model

Maximum Power
Consumption

FGS624
without uplink
with 2 CX4+iXFP
with 2 XFP+1XFP
with Combo+1XFP

48 W
63 W
67 W
65 W

FGS648
without uplink
with 2 CX4
with 2XFP
with Combo

94 W
102 W
106 W
104 W

FGS624 power drawn from outlet with 1 power supply
without uplink
with 2 CX4+1XFP
with 2XFP+1XFP
with Combo+1XFP

99 W
121 W
121 W
121 W

Advertising