3 behaviour after power-on – West Control Solutions Pro-16 User Manual

Page 10

Advertising
background image

Operation

9499-040-93811 / 59537-1

Page 10 of 88

Pro-16

The setting in the function level or in BlueControl® (engineering tool), individual layers can
be locked or made accessible by entering the password in.
Individual parameters accessible without password must be copied to the extended
operating level via BlueControl

®

.

When supplied, all levels are fully accessible,
Password

PASS = OFF

3.2.1

Operating Level

See also chapter 3.4 Operating level

And chapter 3.6 Function level

3.3 Behaviour after power-on

After supply voltage switch-on, the unit starts with the operating level.
The unit is in the condition which was active before power-off.
If the controller was in manual mode before power-off, the controller starts with the last
correcting value after switching on again.