Level, Othr – West Control Solutions Pro-16 User Manual

Page 38

Advertising
background image

Configuration

level

9499-040-93811 / 59537-1

Page 38 of 88

Pro-16

6

è -Key function (see chapter 3.6 page 14)

7 Limit

1

8 Limit

2

9 Limit

3

P.oFF

Programmer Run/Stop (see page )

0

0

no function (switch-over via interface is possible)

2 DI1

3 Di

2

4

DI3 (only visible with OPTION)

5

DI4 (only visible with OPTION)

6

è -Key function (see chapter 3.6 page 14)

7 Limit

1

8 Limit

2

9 Limit

3

di.Fn

Function of digital inputs (valid for all inputs)

0

0 direct

1 inverse

2

toggle key function

fDI1
fDI2
fDI3
fDI4

Forcing di1/ di2 / di3 (only visible with BlueControl!)

0

0 No

forcing

1

Forcing via serial interface

othr

Name

Value range

Description

Default

bAud

Baudrate of the interface (only visible with OPTION)

2

0 2400

Baud

1 4800

Baud

2 9600

Baud

3 19200

Baud

Addr

1...247

Address on the interace (only visible with OPTION)

1

PrtY

Data parity on the interface (only visible with OPTION)

1

0

no parity (2 stop bits)

1 even

parity

2 odd

parity

dELY

0...200

Delay of response signal [ms] (only visible with OPTION)

0

Unit

Unit

1

0 without

unit

Advertising