Supply, Pressure, and Return Hydraulics

Service Manual — Models 644B, 6K, 844C, 8K, 1044C, 10K

5-67

Control Valve Functions

The following is a description of the seven control valves in the control
manifold assembly and their function.

Compensator Valve

The Compensator (CS) valve is a load sensing bypass type with priority
relief. It allows hydraulic fluid to flow to steering on demand. It limits
pressure in the steering circuit to 2200 psi. Pressure can be checked at the
Steering Pressure Gauge (PSG) port. A pressure reading can be taken
from the steering diagnostic port (see Fig. 5-58 on page 5-90). When not
steering, all flow goes out the Excess Flow (EF) port.

The CS valve will distribute priority flow to the steer orbitrol using a signal
sent from the load sense port on the steer orbitrol. There is a built-in
adjustment relief to keep steer pressure at approximately 2250 psi. Flow
that is not used for steering is available downstream for boom functions.

Check Valve

When charging of accumulator or pressurization of Excess Flow (EF) port,
the Check Valve (CV) allows flow to charge accumulator. The CV flows in
one direction only — towards Accumulator (AC) port.

Valve Specifications

Description

Load sensing bypass type with priority relief

Priority Relief Setting

2250 ± 50 psi @ 1 gpm

Maximum Operating Pressure

3000 psi

Nominal Flow Capacity

40 gpm (Inlet)

Maximum Control Flow

20 gpm

Bias Pressure

150 psi

Load Sense Signal

Static

Service Seal Kit

P33199

Valve Specifications

Description

Poppet type check valve

Crack Pressure

5 ± 1 psi

Maximum Operating Pressure

3500 psi

Nominal Flow Capacity

6 gpm

Maximum Internal Leakage

20 gpm

Bias Pressure

5 Drops/Minute

Service Seal Kit

P33195