Supply, Pressure, and Return Hydraulics

5-68

Service Manual — Models 644B, 6K, 844C, 8K, 1044C, 10K

Logic Valve

The Logic (LC) valve opens and closes dependent upon a pilot signal from
the Pilot Unloading (PU) valve.

Pilot Directional Valve

The Pilot Directional (PD) valve allows oil downstream to the pressure
reducing valve once the engine has started and back pressure meets or
exceeds 50 psi. When the engine is running, it allows flow to joysticks.
When engine shuts down, back pressure is lost and the PD assumes a
closed position.

Valve Specifications

Description

Poppet type logic valve, vent to open, side
orifice

Maximum Operating Pressure

3500 psi

Maximum Leakage

5 Drops/minute

Pilot Flow @ 1000 psi

60 Cubic Inches/Minute

Bias Pressure

50 psi

Pilot Ratio

2:1

Service Seal Kit

P33197

Valve Specifications

Description

Three-way, two-position, directional valve;
external pilot to shift

Minimum Shift Pressure

50 psi @ 1 Pilot Port

Maximum Operating Pressure

3500 psi

Nominal Flow Capacity

2 gpm

Maximum Internal Leakage

5 Cubic Inches/Minute

Service Seal Kit

P33196