Transmission

8-22

Service Manual — Models 644B, 6K, 844C, 8K, 1044C, 10K

3. Using a DMM set to meter resistance, test for resistance between

blade 86 and blade 85. A Bosch brand relay should meter 85 ±5 W. A
Potter & Brummfield brand relay should meter 90 ±10% W.

4. Connect a 12 volt lead to blade 86. Connect a ground lead to blade 85.

Using a DMM set to test continuity, test for continuity between blade 30
and blade 87.

Note:With 12 volts at blade 86 and blade 85 grounded, continuity between

blade 30 and blade 87 must be present; if not, replace the relay.

5. Disconnect the 12 volt lead to blade 86. Using a DMM set to test

continuity, test for continuity between blade 30 and blade 87A.

Note:With no 12 volt signal at blade 86, continuity between blade 30 and

blade 87A must be present; if not, replace the relay.