Frame level indicator, Description, Adjustment – Lull 6K Service Manual User Manual

Page 519

Advertising
background image

Frame Tilt and Oscillation

Service Manual — Models 644B, 6K, 844C, 8K, 1044C, 10K

7-17

Installation, Counterbalance Valve

1. Lubricate O-rings with clean hydraulic oil.

2. Install each cartridge in manifold block and torque to 30–35 ft-lbs.

Frame Level Indicator

Description

Fig. 7-10: Frame Level Indicator

(Ref. Fig. 7-10) The Frame Level Indicator shows the lateral (side-to-side)
angle of the frame relative to level ground. Indicator range is from 0° to 10°
left or right, in increments of one degree. When the ball is centered (0°),
the machine is laterally level. The frame tilt feature may be used to correct
machine angles up to 12.5° to the left or right. See “Frame Tilt Control
Valve” on page 7-3.

Adjustment

Fig. 7-11: Leveling the Frame

0

5

10

5

10

H1004

K

1026

Carpenter’s Level

Advertising