A–8

Specifications and Supplemental Information

To allow convenient control of the Traverse and Sync functions
through SCANport adapters, an alternate definition of the SCANport
type 2 command can be selected. See also [Alt Type 2 Cmd].

Alternate Logic Control
Structure

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

Bit 14

Direction

5

4

No Command

0

0

Forward

0

1

Reverse

1

0

Hold Direction

1

1

Time

9/11 8/10

No Command

0

0

Time 1

0

1

Time 2

1

0

Hold Time

1

1

Reference

14 13 12

No Command 0

0

0

Freq Select 1

0

0

1

Freq Select 2

0

1

0

Preset Freq 3 0

1

1

Preset Freq 4 1

0

0

Preset Freq 5 1

0

1

Preset Freq 6 1

1

0

Preset Freq 7 1

1

1

Start

1 = Start
0 = Not Start

Stop

1 = Stop
0 = Not Stop

Jog

1 = Jog
0 = Not Jog

Clear Faults

1 = Clear Faults
0 = Not Clear Faults

Local

1 = Local Lockout
0 = Not Local

Sync Enable

1 = Enabled
0 = Not Enabled

Traverse Enable

1 = Enabled
0 = Not Enabled

Reference Select

Decel Time

Accel Time