Chapter 1, Information and precautions, Manual objectives – Rockwell Automation 1336Z SPIDER - FRN 2.xxx-5.xxx User Manual

Page 7: Catalog number explanation, Conventions used in this manual, General precautions, Chapter, 1336z

Advertising
background image

Chapter

1

Information and Precautions

Chapter 1 provides information on the general intent of this manual,
gives an overall description of the 1336

SPIDER

Adjustable

Frequency AC Drive and provides a listing of key drive features.

Manual Objectives

This publication provides planning, installation, wiring and
diagnostic information for the Stand-alone (full I/O) and PLC

control (limited I/O) 1336

SPIDER

Drive. To assure successful

installation and operation, the material presented must be thoroughly
read and understood before proceeding. Particular attention must be
directed to the Attention and Important statements contained within.

Catalog Number Explanation

The diagram below describes the SPIDER catalog numbering system.

Conventions Used in this
Manual

To help differentiate parameter names and display text from other text
the following conventions will be used:

Parameter Names will appear in [brackets]

Display Text will appear in “quotes”

General Precautions

1336Z

First Position

Bulletin Number

P

Second Position

Drive Types

Letter

Type

P

PLC Control

S

Stand-Alone
Control

022

Fourth Position

Peak Current Rating

1

Code Peak Current

022

21.6A

036

36.0A

060

60.0A

GM1

Sixth Position

Communication Options

Code Description

GM1

Single Point Remote I/O

GM2

RS-232/422/485, DF1 &
DH485

GM5

DeviceNet™

GM6

Enhanced DeviceNet

A

Third Position

Voltage

Letter

Voltages

A

200-240V AC or
310V DC

N

Fifth Position

Enclosure Type

Code Type

N

IP 20 (Open Type)
with Line Choke

AE

IP 20 (Open Type)
with EMC Filter

010

9.9A

017

16.5A

033

33.0

B

380-480VAC or
513-620V DC

1

This current is only possible with synchronous motors and for spinning applications. For actual motor current rating, refer to Appendix A.

!

ATTENTION: Only personnel familiar with the 1336
SPIDER

Adjustable Frequency AC Drive and associated

machinery should plan or implement the installation, start-up
and subsequent maintenance of the system. Failure to comply
may result in personal injury and/or equipment damage.

!

ATTENTION: An incorrectly applied or installed drive can
result in component damage or a reduction in product life.
Wiring or application errors, such as, undersizing the motor,
incorrect or inadequate AC supply, or excessive ambient tem-
peratures may result in malfunction of the system.