Pulse in scale, Encoder ppr – Rockwell Automation 1336Z SPIDER - FRN 2.xxx-5.xxx User Manual
Page 90
7–18
Programming
[Pulse In Scale]
– Stand-Alone Version Only
Provides a scaling factor for the pulse input.
Example:
4 Pole Motor, 60 Hz = Max. Speed.
The 1336-MOD-N1 option outputs 64 Hz/Hz. At full analog
reference, the pulse input to the drive will be 60 Hz x 64
Hz/Hz = 3840 pulses/sec.
Parameter Number
264
Parameter Type
Read and Write
Display Units / Drive Units
Factor / Pulses per Rev
Factory Default
64 PPR
Minimum Value
1
Maximum Value
4096
[Encoder PPR]
– Not Available on the SPIDER Drive
This parameter sets the scaling for encoder feedback
speed regulation. Enter the actual encoder pulses per
revolution
Parameter Number
46
Parameter Type
Read and Write
Display Units / Drive Units
Factor / Pulses per Rev
Factory Default
1024 PPR
Minimum Value
1
Maximum Value
4096
Scale
Factor
Incoming Pulse Rate (Hz)
Desired Command Freq.
=
Scale Factor =
3840 Hz
60 Hz
= 64