Specifications and Dimensions

A-7

1394 System Power Dissipation Specifications

The following section contains the power dissipation characteristics of
the 1394 system modules, axis modules, and internal shunt resistors.

System Modules

Axis Modules

1

The AM50/75 are designed to mount with the rear heat sink extended outside the customer-supplied enclosure. If
the modules are mounted entirely inside the customer supplied enclosure, the full power dissipation is inside the
cabinet (the sum of the inside/outside columns).

2

The AM50/75-IH are designed to mount entirely inside the customer-supplied enclosure.

IMPORTANT

Use the power dissipation figures shown below to
calculate cumulative system heat dissipation to
ensure that the ambient temperature inside the
enclosure does not exceed 50° C (122° F). To
calculate total power dissipation, add the dissipation
of the system module to the dissipation of the axis
module(s).

Percentage of Rated
Power Output

Power Dissipation

Watts

1394x-SJT05-x

1394x-SJT10-x

1394x-SJT22-x

20

66

70

100

40

70

77

150

60

73

84

200

80

77

81

250

100

80

98

300

Percentage of Rated
Power Output

Power Dissipation

Watts

Total

Inside Cabinet

Outside Cabinet

AM03

AM04

AM07

AM50

1

and
AM50-IH

2

AM75

1

and
AM75-IH

2

AM50

1

AM75

1

AM50

1

AM75

1

20

24

27

33

56

85

18

18

38

67

40

30

36

48

95

145

18

18

77

127

60

36

45

63

139

212

18

18

138

194

80

42

54

78

183

279

18

18

165

261

100

48

63

93

227

346

18

18

209

324