Connecting 1326AB/AS (resolver) Motor Power
When using 1326AB/AS motors with resolver feedback, the thermal
switch and brake wires are included in the motor power cable (1326-
CPx1-xxx). To improve the EMC performance of your system, route
the motor brake and thermal switch wires to TB1 (as shown in Figure
3.10) and reference Thermal Switch and Brake Interconnect Diagrams
on page B-9 for the interconnect diagram.
Figure 3.10
Motor Power Cable (1326-CPx1-xxx)
Status
DANGER
RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY
EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.
SERCOS System Module
TB1
TB2
TB1
TB2
Motor Brake and
Thermal Switch Wires
1326-CPx1-xxx Motor Power Cable
1326-CPx1-xxx Motor Power Cable