Connecting 1326AB/AS (resolver) Motor Power

When using 1326AB/AS motors with resolver feedback, the thermal
switch and brake wires are included in the motor power cable (1326-
CPx1-xxx). To improve the EMC performance of your system, route
the motor brake and thermal switch wires to TB1 (as shown in Figure
3.10) an
d reference Thermal Switch and Brake Interconnect Diagrams
on page B-9 for the interconnect diagram.

Figure 3.10
Motor Power Cable (1326-CPx
1-xxx)

Status

DANGER

RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY

EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.

SERCOS System Module

TB1

TB2

TB1

TB2

Motor Brake and

Thermal Switch Wires

1326-CPx1-xxx Motor Power Cable

1326-CPx1-xxx Motor Power Cable