Publication 1394-IN002B-EN-P — February 2004

3-24

Connecting Your 1394 SERCOS Interface System

3. Gently pull on each TB1 wire to make sure it does not come out

of its terminal. Re-insert and tighten each loose wire.

4. Insert the first connector plug (TB1) into the front-most mating

half under the axis module.

5. Connect the appropriate thermal switch control wires to the

second connector plug (TB2) in the kit (pins 3 and 4) and tighten
the TB2 screws. Refer to Appendix B for thermal switch
interconnect diagrams.

6. Connect the appropriate brake control wires to the second

connector plug (TB2) in the kit (pins 1 and 2) and tighten the
screws. Refer to Appendix B for brake interconnect diagrams.

7. Gently pull on each TB2 wire to make sure it does not come out

of its terminal. Re-insert and tighten each loose wire.

8. Insert the second connector plug (TB2) into the rear-most mating

half under the axis module.

9. Go to Wiring the Relay Outputs Connector on page 3-25.

ATTENTION

!

To avoid damage to your motor, monitor the
thermal switch for overheat conditions.