Figure 3.15 – Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System Installation Manual User Manual
Page 87
Publication 1394-IN002B-EN-P — February 2004
Connecting Your 1394 SERCOS Interface System
3-33
4. Repeat steps 2 and 3 for all remaining I/O connector housing
wires.
5. Plug the connector housings into the appropriate I/O connector
on the front of the system module (refer to figures 2.1 or 2.2 for
connector locations).
6. Secure the I/O wires by slipping a plastic tie-down through the
tie-down anchor (refer to figures 2.1 or 2.2 for tie down anchor
locations) and bundle the wires together.
Figure 3.15
Wiring I/O Cables
Replacement connector housings are included in the system module
connector kit (part number 1394C-CCK-D). Each terminal has a spring
type clamping mechanism which firmly grips the bare wire.
Axis 0
Axis 1
Axis 2
Axis 3
1
2
3
4
5
6
7
8
Blade thickness
:
0.5 mm (0.02 in.)
1394 SERCOS interface
Control Board
1394C-SJTxx-D