Figure 3.15 – Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System Installation Manual User Manual

Page 87

Advertising
background image

Publication 1394-IN002B-EN-P — February 2004

Connecting Your 1394 SERCOS Interface System

3-33

4. Repeat steps 2 and 3 for all remaining I/O connector housing

wires.

5. Plug the connector housings into the appropriate I/O connector

on the front of the system module (refer to figures 2.1 or 2.2 for
connector locations).

6. Secure the I/O wires by slipping a plastic tie-down through the

tie-down anchor (refer to figures 2.1 or 2.2 for tie down anchor
locations) and bundle the wires together.

Figure 3.15
Wiring I/O Cables

Replacement connector housings are included in the system module
connector kit (part number 1394C-CCK-D). Each terminal has a spring
type clamping mechanism which firmly grips the bare wire.

Axis 0

Axis 1

Axis 2

Axis 3

1

2

3

4

5

6

7

8

Blade thickness

:

0.5 mm (0.02 in.)

1394 SERCOS interface

Control Board

1394C-SJTxx-D

Advertising