Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System Installation Manual User Manual

Page 70

Advertising
background image

Publication 1394-IN002B-EN-P — February 2004

3-16

Connecting Your 1394 SERCOS Interface System

Wiring Main Input Power

To wire the main input power connector:

1. Prepare the incoming three-phase power wires for attachment to

the input power connector by removing 10 mm (0.375 in.) of
insulation.

2. Route the three-phase power wires (U, V, W, and PE) to your 1394

system module.

3. Connect the system module ground wire from the system module

single point bond bar to the bonded ground bar or bonded
cabinet ground bus on the subpanel (as shown in Figure 3.7). For
more information on bonding, refer to Chapter 1.

4. Insert the incoming power wires into the input power connector

plug as follows and tighten the four connector plug screws.

5. Gently pull on each wire to make sure it does not come out of its

terminal. Re-insert and tighten any loose wires.

6. Insert the input power connector plug into the input power

connector on the bottom of the system module (refer to Figure 2.1
for the connector location).

IMPORTANT

Use caution not to nick, cut, or otherwise
damage strands as you remove the insulation.

Insert the wires labeled:

Into connector terminals
labeled:

U

U

V

V

W

W

Ground

PE

ATTENTION

!

To avoid personal injury or damage to
equipment, verify that keys are inserted into the
beveled slots above terminals V and W of the
input power connector plug and PE and COL on
the system module input and shunt power
connectors, respectively. If the keys are missing,
refer to Installing Your 1394C Power Connector
Key Kit Installation Instructions
(publication
1394-IN023x-EN-P).

Advertising