3 d-ram tests, Figure 2-46 d-ram test – Canon FAX-L1000 User Manual

Page 125

Advertising
background image

2-69

FAX-L1000 Chapter 2: Operating Instructions

3.4.3 D-RAM tests

Pressing the numeric key 1 from the test mode menu selects the D-RAM tests. D-RAM Test 1
writes data to the entire D-RAM region and reads it out to check that operations are correct.
D-RAM Test 2 just reads data at high speed. This test can be used to check operations when
optional memory has been added.

Figure 2-46 D-RAM Test

Before D-RAM test, output all image data in image memory.
When D-RAM test is performed, all image data are cleared.

1:D-RAM

3456K

. . . . .

∗ ∗ ∗ ∗ ∗ ∗

1:D-RAM

3456K

complete

(no error)

3456K: D-RAM total memory capacity (bytes)
(7552 K: When 4 Mbyte Memory added)
(11648 K: When 8 Mbyte Memory added)

: Indicates an address for which write testing is complete.

. : Indicates an address for which read testing is complete.

Operating

Normal end

WRT= 33CC RD= 33EC
ADR= BF840201

Error

Error display

Restart by pressing
Start key.

Error display

WRT : data written
RD :

data read

ADR : address

1:D-RAM

3456K

complete

(error)