Figure 5-35 adjustment of separation guide – Canon FAX-L1000 User Manual

Page 446

Advertising
background image

5-88

FAX-L1000 Chapter 5: Appendix

3.4.5 Installation Position Adjustment of Separation Guide of

Envelope Feeder (adjustment of gap between separation guide
and lower separation roller)

a) When

Normally, the separation guide and the top cover of the envelope feeder must be removed
as one. However, if only the separation guide has been removed for unavoidable reason, or
it needs to be replaced due to deformation, make the adjustment as shown below.

b) Tools

Tool

Use

1.6mm thickness gauge (RY9-0123)

Measuring gap between the separation guide
and the lower separation roller

c) Adjustment

(1) Install the separation guide.
(2) Insert the 1.6mm thickness gauge (RY9-0123) between the separation guide and the

lower separation roller.

(3) Fix the separation guide with 1.6mm gap between the separation guide and the lower

separation roller.

Figure 5-35 Adjustment of Separation Guide

RY9-0123

1.6mm

Thickness gauge

Separation guide

1.6mm

Separation guide

Lower separation roller

Thickness gauge

(1.6mm, RY9-0123)