Canon FAX-L1000 User Manual

Page 540

Advertising
background image

5-182

FAX-L1000 Chapter 5: Appendix

##1058 [TX/RX] a) Bearer capability not presently available

b) Call has not been accessed, break down through time-out

Cause a):

Indicated above

Solutions a):

(1) Re-check the contract, and re-transmit.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

Cause b):

Indicated above

Solutions b):

(1) Re-check the telephone number, then re-establish communication.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

##1059 [TX/RX] Called party is busy (all B-channel are occupied)

Cause:

Indicated above

Solutions:

(1) Wait a while, then re-transmit.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

##1060 [TX/RX] Disconnection from network

Cause:

Indicated above

Solutions:

(1) Re-check the phone number and try the call again.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

Advertising