b-6) Check after the Kit Installation

After installing the kit, carry out the following procedure to ensure that the kit is properly
identified by the main unit.

(1) Referring to the flow chart, enter service data registration, then check that the ROM

versions are displayed.

Figure 5-54 ROM Version Check

(2) After confirming this, push the

Stop

button, which will put the machine into a

standby condition.

(3) If the ROM versions are not displayed, return to

b-3) Attaching the kit

or

b-4)

Replacing the ROM

, re-attach the kit or the ROM, and then re-check the display.

(4) Perform a communications test to make sure that transmission and reception are

normal.

(5) If a problem occurs during the test, perform the following:

. Check that the ISDN cable is securely connected.
. Check that the kit is securely connected.
. Refer to the

Service Manual, Chapter 5, 3.6.7 Maintenance and service.

b-7) Removing the kit

When removing the kit or the ROM, perform the steps in

b-3) Attaching the kit

or

b-4)

Replacing the ROM

, in reverse order. Be sure to remove them only after turning the

power off.

Data Registration

#

SERVICE MODE
#9 ROM

Set

MAIN: EC-01-01
991208 C114 FFFF

OPT: EC-01-01
991208 D96B FFFF

OPT2: EC-01-01
991208 824C FFFF

Standby

Stop

Display #9 ROM by
pressing

or

button

Main ROM version on SCNT board

Main ROM version on G4 board

Slave CPU (V853) version on G4 board