3 energy save standby (ess), Figure 3-53 system block diagram, Pcnt psu – Canon FAX-L1000 User Manual

Page 249

Advertising
background image

3-105

FAX-L1000 Chapter 3: Technical Reference

3.3 Energy Save Standby (ESS)

a) Function

ESS is an energy save function for minimizing power loss during standby.
During ESS, the ESS control section of the system control IC inside the SCNT board halts
all oscillators other than the real time clock (RTC) IC in order to reduce power loss.
Because of this, the operation of ICs etc. receiving clock supply from the oscillators is
halted. Also, the functions of parts of the system control IC itself which receive clock
supply from the oscillators are halted as well. Only those parts which receive clock supply
from the real time clock IC continue to operate, and in this manner an idle condition (sleep
mode) is created. Additionally, the main CPU and modem are also put into sleep mode by a
sleep mode signal from the system control IC.
Also, the supply of power other than the 5V from the PSU will be interrupted, and the
operation of ECNT board and other boards will be halted.
Power standby is performed in this way, through the halting of the operations of some of
electrical parts on the ECNT and SCNT boards.

The main functions of the ESS control section in ESS mode are as follows:
• Display management

Control LCD display on the OPCNT board.

• Startup factor detection

Monitor startup factors all the time.

• Main unit start management Enable the main unit when a startup factor is detected.

Figure 3-53 System Block Diagram

Sleep mode

Real Time

Clock IC

Main CPU

MODEM IC

LCD/LED display

Display signal

Control

signal

Sleep

mode

signal

Oscillators

Other ICs

SCNT Board

System Control IC

(ESS Control Section)

Operation

stop

Startup factors

Control signal

Control signal

Stop

signal

+5V

PCNT

PSU