Canon FAX-L1000 User Manual

Page 225

Advertising
background image

3-81

FAX-L1000 Chapter 3: Technical Reference

b-2) Probing (Phase 2)

The line characteristics are measured and modulation-related parameters, such as symbol
rate, are set.

• Transmitter

Abbre-

Signal

viation

Meaning

Remarks

INFO sequence

INFO0c

Tone B

B

Tone B

B

Probing signal

L1

L1

Probing signal

L2

L2

• Receiver

Abbre-

Signal

viation

Meaning

Remarks

INFO sequence

INFO0a

Tone A

A

Tone A

A

INFO sequence

INFO0h

Indicate modem capabilities,
such as baud
rate and frequency
transmission function (two
frequency bands
used to measure line
characteristics), and request
adjustment.

Modem synchronization with
a 1200-Hz tone signal.

Tone signal for analyzing line
characteristics by probing.
Transmit the signal at a level 6
dBm higher than the transmission
signal level set by the attenuator.

Transmission
speed: 600bps

The phase of the B-
signal is inverted 180
degrees from the phase
of the B signal.

Probing: Measurement
of line characteristics.
Tone signal in the range
150 to 3750 Hz in 150-
Hz steps.

Report the modem capa-
bilities, such as baud
rate and frequency
transmission ability.

Modem synchronization with
a 2400-Hz tone signal.

Report the pre-emphasis filter
and baud rate used for data
transmission based on the
result
of analysis of the probing
signal.

Transmission
speed: 600bps

The phase of the A-
signal is inverted 180
degrees from the phase
of the A signal.

Transmission
speed: 600bps

Advertising