Canon FAX-L1000 User Manual

Page 202

Advertising
background image

3-58

FAX-L1000 Chapter 3: Technical Reference

• This fax machine does not have "-ACVIN signal".
• If the ECNT board CPU detects with the thermistor that the fixing heater temperature is

over 428°F (220°C), it cuts off the power to the fixing heater (Software protection).

• If the ECNT board fixing heater protective circuit detects that the fixing heater temperature

is 464°F (240°C), it cuts off the power to the fixing heater regardless of the ECNT board
CPU output (Hardware protection).

• If the fixing heater temperature is over 446°F (230°C), the thermal fuse in the fixing film

unit blows, turning the fixing heater off.

• The ECNT board CPU detects thermistor broken wire in the following cases, and assesses

warm-up error or abnormally low temperature.

1. The thermistor, in the low-temperature detection mode, does not exceed about

68°F(20°C) within about 0.7 seconds after the heater is turned ON.

2. The thermistor, in the high-temperature detection mode, does not exceed about

122°F(50°C) within about 5.0 seconds after the heater is turned ON.

3. The thermistor, in the high-temperature detection mode, detects over about 122°F(50°C)

after the heater is turned ON. Then the output voltage from the thermistor is more than
about 3.4V for more than about 100ms continuously.

• The ECNT board CPU detects heater broken wire in the following cases and assesses warm-

up error or abnormally low temperature.

1. The thermistor, in the low-temperature detection mode, does not rise +50°F(+10°C) from

the initial temperature within about 2.5 seconds after the heater is turned ON.

2. The thermistor, in the low-temperature detection mode, does not rise +68°F(+20°C) from

the initial temperature within about 2.5 seconds after rising +50°F(+10°C) from the
initial temperature since the heater is turned ON.

3. The thermistor, in the high temperature detection mode, does not exceed about

320°F(160°C) within about 20 seconds after rising +68°F(+20°C) from the initial
temperature since the heater is turned ON.

4. When the thermistor is in the high temperature detection mode and the initial

temperature is 185°F(85°C) or below, the temperature does not exceed about
320°F(160°C) within about 20 seconds after the heater is turned ON.

Advertising