Canon FAX-L1000 User Manual

Page 530

Advertising
background image

5-172

FAX-L1000 Chapter 5: Appendix

##1002 [TX/RX] No route to specified transit network.

Cause:

Indicated above

Solutions:

(1) Re-check the method of connection to the designated relay

network.

(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

##1003 [TX/RX] a) No route to destination.

b) Designated bearer service not implemented.

Cause a):

Indicated above

Solutions a):

(1) Re-check the phone number and try the call again.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

Cause b):

Indicated above

Solutions b):

(1) Re-check the designated bearer service.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

##1006 [TX/RX] Channel unacceptable.

Cause:

Indicated above

Solutions:

(1) Wait a while and then transmit, because the other terminal is in

the middle of a transmission.

(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in

#4C ISDN BASIC, [G4/G3 Fallback]

and

[Speech Fallback]

.

(4) Take countermeasures as outlined in

D-channel connection

error

in

this Chapter, 3.6.6 Maintenance and service, c)

Communication problems.

(5) Make an inquiry to the maker of the Switching equipment.

Advertising