Pausing the Jog Function

You can pause the JOG cycle by pushing
the Stop button once at any time during the
JOG cycle.

1.

If you pause the Jog On cycle the JOG
Hold display appears. (See Fig. 3-32)

FIG. 3-32 PAUSING JOG IN THE JOG ON CYCLE

2.

If you pause the Jog Off cycle the
JOG Hold display appears. (See Fig.
3-33)

FIG. 3-33 JOG PAUSED 1.0 SECOND INTO THE JOG

OFF SEQUENCE

Discharge Function

After a fill completes, which may include a JOG if neces-
sary, you have the option to Discharge the Fill. Once the
instrument has determined that the fill is within the target
window, it discharges the fill before returning to the Fill ON
Display or the Fill Standby Display depending on which fill
cycle you just finished.

The Discharge and Auto Discharge Function are user select-
able and must be turned ON during Setup. (To turn the Dis-
charge Functions ON, see the HI 3010 Installation and
Service Manual for instructions)

Step 1. The Filler/Dispenser then gets set to Discharge the

current fill. The Awaiting Command to Discharge
display appears if Auto Discharge is Off and Dis-
charge is On. (See Fig. 3-34) To start the discharge
push the Start button. The Command to discharge
can also come from a PLC or other controller.

FIG. 3-34 AWAITING COMMAND TO DISCHARGE

DISPLAY

Step 2. If the OK to Discharge is ON, the instrument

checks to see if it is OK to discharge. The instru-
ment also checks to see if the discharge gate is
open.

If it is OK to discharge and no DIS-
CHARGE GATE NOT OPEN alarms
appear. The instrument opens the dis-
charge gate and discharges the current fill.

Step 3. The system discharges the current fill. The Dis-

charge display appears showing a steady loss in
weight. If there is no loss in weight and you have
enabled the Auto Auxiliary function the instrument
turns on the auxiliary timer at the same time. (See
Fig. 3-35)

FIG. 3-35 AUTO AUXILIARY ON DISPLAY

If you want to pause the Auxiliary func-
tion. Press the Stop button once. The Actu-
ate for Discharge Display changes from
ON to HLD. (See Fig. 3-36)

To restart the actuate Auxiliary function
press the Start button.

FIG. 3-36 PAUSING THE ACTUATE FUNCTION