Fast feed on alarm no slow feed alarm, Fig. 4-56 fast dispense on, 57 resume filling slow display – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 57: Fast feed on display fig. 4-59 underdispense alarm, E alarm, No slow feed alarm

Advertising
background image

HI 3010 Filler/Dispenser/IBC

44

User Guide

FIG. 4-55 FAST DISPENSE ON

FIG. 4-56 RESUME FILLING SLOW DISPLAY

Fast Feed On Alarm

- - - - - ALARM CONDITION - - - - -

If the Fast Dispense Gate valve or feeder
does not open close or turn off at the end
of a cycle, the FAST FEED ON alarm
appears on the display. (See Fig. 4-57)

FIG. 4-57 FAST FEED ON DISPLAY

1.

Determine why the Fast Feed is On
and correct the problem.

2.

Press the Clear button to clear the
alarm.

3.

If the weight is Not within the target
window and you do not have the JOG
function on, the dispense is not
accepted and an UNDER DISPENSE
alarm (See Fig. 4-58) or OVER DIS-
PENSE (See Fig. 5-59) alarm appears
depending on the weight dispensed.

FIG. 4-58 UNDERDISPENSE ALARM

FIG. 4-59 OVERDISPENSE ALARM

No Slow Feed Alarm

- - - - - ALARM CONDITION - - - - -

If the Slow Dispense Gate valve or feeder
does NOT open or come on, the NO
SLOW FEED alarm appears on the dis-
play. (See Fig. 4-60)

FIG. 4-60 NO SLOW FEED ALARM

1.

Determine why there is no Slow Feed
and correct the problem.

2.

Press the Clear button to clear the
alarm. The Resume Dispense Slow
Press Start display appears, for dual
speed, sequential dispensing applica-
tions. (See Fig. 4-61)

3.

Press the Start Button to resume the
slow dispense

Advertising