CHAPTER 5
Operating Procedures/IBC Dispenser

FIG. 5-24 IBC DISPENSE DISPLAY/WAITING ON

NOTE:

From this point on the IBC dispensing process is
automatic and under normal conditions does not
require operator intervention. The displays pro-
vided are to illustrate the procedures the instru-
ment goes through and the displays associated
with these procedures. It is highly unlikely that
you will be required to manually intervene except
when the Alarm conditions occur. A list of the
Alarm conditions and remedies are provided after
this section.

Step 9.

If the “OK to Dispense” function is turned ON, in
addition to the motion and autotare, the instru-
ment checks to see that the system is ready to dis-
pense. This means that the instrument can check
a proximity switch for container positioning, a
sensor detecting that a valve is open or closed, an
OK to Dispense instruction sent from a PLC or
DCS and so on.

If it is OK to Dispense, the Filler/Dis-
penser/IBC starts dispensing and returns to
the Dispense Display. (See Fig. 5-25)

NOTE:

The “Fast Dispense” appears for both Single or
Dual Speed IBC Dispensing.

Ingredient = Granules

Current dispensed amount = 0.00 lbs out
of 1000.00 lbs. loss in weight for cycle
number 1.

Cycle = 1 out of 11 cycles.

IBC Dispenser Status = FAST DISPENSE
ON

FIG. 5-25 FAST DISPENSE ON DISPLAY

If it is NOT OK to Dispense, an alarm
appears in the display.

Step 10.

If the Fast Dispense Display appears showing a
steady weight (no loss-in-weight) and there is no
indication of motion. If you have enabled the
Auto Auxiliary function the instrument turns on
the auxiliary timer at the same time. (See Fig. 5-
26)

FIG. 5-26 AUTO AUXILIARY ON DISPLAY

If you want to pause the auxiliary function.
Press the Stop button once. The Auxiliary
Display changes from ON to HLD. (See
Fig. 5-27)

To restart the auxiliary function press the
Start button. The fast dispense with vibra-
tion appears. (See Fig. 5-28)

FIG. 5-27 PAUSING THE AUXILIARY FUNCTION

FIG. 5-28 FAST DISPENSE/WITH AUXILIARY ON

NOTE:

The auxiliary function will stop at the end of its
pre-programmed time.

NOTE:

If you want to Pause the auxiliary function press
the Stop button one time. If you want to Stop the
auxiliary function press the Stop button two
times. The instrument returns to the Standby
Mode and does not process any more cycles.