Dispense alarms, Over refill alarm refill timeout alarm, Standby display – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 54: Over refill alarm, Refill time-out alarm

Advertising
background image

41

CHAPTER 4
Operating Procedures/Dispenser

FIG. 4-41 SLOW DISPENSE DISPLAY

3.

If the dispense is within the target
window and you do not have the Dis-
charge Function turned ON (See Dis-
charge Function above), the
instrument returns to the Waiting On
Display, repeats the motion check,
autotares and/or checks the OK to
Dispense processes and begins dis-
pense cycle number 2, then 3, 4 and so
on. (See Fig. 4-42)

4.

If the dispense is within the target
window and it is the last dispense
cycle (See Fig. 4-43) of a dispense
sequence, the instrument goes to
Standby and the Standby Display
appears. (See Fig. 4-43)

FIG. 4-42 LAST CYCLE IN BERRIES SEQUENCE

FIG. 4-43 STANDBY DISPLAY

Dispense Alarms

Over Refill Alarm

- - - - - ALARM CONDITION - - - - -

FIG. 4-44 OVER REFILL ALARM

If the Refill exceeds the Refill High set
point or exceeds the capacity of the vessel
and the refill has stopped, the OVER
REFILL ALARM appears. (See Fig. 44)

1.

Correct the Over Refill condition.

2.

Press the Clear button to clear the
alarm. The Dispense Standby display
appears.

Refill Timeout Alarm

- - - - - ALARM CONDITION - - - - -

FIG. 4-45 REFILL TIME-OUT ALARM

If the time taken to Refill exceeds the
Refill Time-out parameter which is set
during configuration, the Refill Time-out
Alarm appears. (See Fig. 4-45) For setup
information check the HI 3010 Installation
and Service Manual.

1.

Check to see why the refill took too
long. If there is an obstruction, or
excessive material bridging, etc. cor-
rect the problem.

2.

If the Refill Time-out was set incor-
rectly. Use your HI 3010 Installation
and Service Manual and reset the
Refill Time-out parameter.

3.

Press the Clear button to clear the
alarm. The Dispense Standby display
appears.