Fig. 3-67 awaiting command to discharge, 70 discharge clogged alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 39

Advertising
background image

HI 3010 Filler/Dispenser/IBC

26

User Guide

1.

Check to see what is causing the Not
OK to discharge alarm to appear.

2.

Correct the problem.

3.

Press the Clear button to clear the
alarm. If Auto Discharge is On, the
instrument looks for an OK to Dis-
charge signal. If Auto Discharge is
Off the Awaiting Command to Dis-
charge display appears. (See Fig. 3-
67)

FIG. 3-67 AWAITING COMMAND TO DISCHARGE

No Discharge Alarm

- - - - - ALARM CONDITION - - - - -

If the instrument determines that the dis-
charge did not occur, the NO DIS-
CHARGE alarm appears. (See Fig. 3-68)

FIG. 3-68 NO DISCHARGE ALARM

1.

Check to see what is preventing the
discharge.

2.

Correct the problem.

3.

Press the Clear button to clear the
alarm. If Auto Discharge is On the
instrument starts monitoring the loss-
in-weight. If the Auto Discharge is
Off the Awaiting Command to Dis-
charge display appears. (See Fig. 3-
69)

FIG. 3-69 AWAITING COMMAND TO DISCHARGE

Discharge Clogged Alarm

- - - - - ALARM CONDITION - - - - -

If during the discharge the discharge gate
becomes clogged, and the Auxiliary is
turned OFF, the DISCHARGE
CLOGGED ALARM appears. (See Fig. 3-
70)

FIG. 3-70 DISCHARGE CLOGGED ALARM

If the Auxiliary is turned ON, the clogged
gate alarm appears if the Auxiliary time
elapses and there is no indication of any
weight change. The DISCHARGE-
CLOGGED ALARM appears. (See Fig. 3-
70)

Step 4. When the discharge is complete, the instrument

closes the discharge gate and returns to the Fill On
display or the Standby Display depending on the
filling cycle.

Discharge On Alarm

- - - - - ALARM CONDITION - - - - -

If the Discharge gate valve or feeder does
not close or stop, a DISCHARGE ON
ALARM appears. (See Fig. 3-71)