Slow feed on alarm fill timeout alarm, 52 resume filling slow, 53 slow feed on alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 36: 54 wait display, 55 timeout alarm, 56 resume filling fast, 57 resume filling slow

Advertising
background image

23

CHAPTER 3
Filler

FIG. 3-52 RESUME FILLING SLOW

3.

Press the Start button to resume slow
filling.

NOTE:

At the beginning of a fill in Dual Speed Simulta-
neous filing, the instrument checks to be sure
there is a slow fill before starting the fast fill. If
there is no Slow Fill the NO SLOW FEED
ALARM is displayed. Clearing the alarm takes
the system back to the Standby state. Any further
fills are not completed.

Slow Feed On Alarm

- - - - - ALARM CONDITION - - - - -

If the Slow Fill Gate valve or feeder does
NOT close or turn off, the SLOW FEED
ON alarm appears on the display. (See Fig.
3-53)

FIG. 3-53 SLOW FEED ON ALARM

1.

Determine why the slow feed is on
and correct the problem.

2.

Press the Clear button to clear the
alarm. The wait timer display appears.
(See Fig. 3-54)

FIG. 3-54 WAIT DISPLAY

3.

If the fill weight is NOT within the
target window and the Jog Function is
not turned on, the fill is not accepted
and an UNDER FILL or OVER FILL
ALARM appears depending on the
weight filled.

Fill Timeout Alarm

If the Fill Timeout function is turned on it
times the fill cycle between the ON and
WAIT modes. If this time is exceeded the
TIMOUT ALARM displays. (See Fig. 3-
55)

FIG. 3-55 TIMEOUT ALARM

1.

Do a physical check of your system
looking for blockages or breaks and
make corrections as necessary.

2.

Press the Clear button to clear the
alarm. Depending on whether you are
operating in single or dual speed and
when the timeout occurred one of the
following displays will appear. (See
Figs. 3-56 or 3-57)

FIG. 3-56 RESUME FILLING FAST

FIG. 3-57 RESUME FILLING SLOW

3.

Press the Start key to resume the fast
or slow fill.

Advertising