Step 11.

When the Net weight on the scale is equal to or
greater than the target weight minus its preact
value the Filler/Dispenser/IBC goes into a wait
sequence to allow things to settle before checking
to see if the dispensed (loss-in-weight) material is
correct. (See Fig. 5-29)

FIG. 5-29 IBC DISPENSE WAIT TIMER DISPLAY

Step 12.

The Filler/Dispenser/IBC automatically checks to
see if the dispense is within the target window.

If the dispense is within the target window
and you do not have the Discharge Func-
tion turned ON (See Discharge Function
below), the instrument returns to the
Standby Display, repeats the motion
check, autotares and/or checks the OK to
Dispense processes and begins dispense
cycle number 2, then 3, 4 and so on. (See
Fig. 5-30)

NOTE:

It is important to note that if Auto Preact is ON,
the Filler/Dispenser/IBC will automatically
adjust the Ingredient Pre-Act parameter insuring
that “UNDERDISPENSE” and “OVERDIS-
PENSE” conditions do not occur or at best are
minimized. The new Preact value is saved for the
ingredient being dispensed and becomes part of
the Ingredient Parameter. It is highly recom-
mended that you turn the Auto Preact function
ON. (For configuration information see the HI
3010 Service Manual for instructions)

FIG. 5-30 BEGINNING DISPENSE CYCLE #2

Step 13.

The IBC Dispenser Continues going through the
dispense cycles until all the dispense cycles are
completed. (See Fig. 5-31)

FIG. 5-31 LAST DISPENSE CYCLE

Step 14.

After completion of all the cycles, the Filler/Dis-
penser/IBC goes back to the Standby Menu. (See
Fig. 5-32)

FIG. 5-32 STANDBY MENU

Step 15.

The Standby Menu enables you to select another
ingredient, Target Weight, Number of Cycles,
and User to begin a new dispensing process.

Jog Function

Step 1. If the loss-in-weight detected in the wait timer state

(See Fig. 5-29) is below the target window and the
Jog Function is turned ON, the Jog function auto-
matically comes on. (See Fig. 5-33)

FIG. 5-33 JOG ON DISPLAY

Step 2. The Filler/Dispenser goes through one (1) JOG

sequence that was previously set up. (See Fig.5-
34) To set up the JOG Parameters see the HI 3010
Installation and Service Manual.