1.

The Operator needs to determine why
the system LOST OK to DISPENSE
by checking for problems with the
electrical and /or mechanical systems.

2.

Once the problem has been fixed,
push the Clear button to clear the
Alarm.

3.

If the OK to dispense was lost while
in the fast or slow dispense mode the
instrument asks if you want to
Resume the fast dispense (See Fig. 4-
51) or slow dispense (See Fig. 4-52).
To resume the dispense press the Start
button. If you do not want to resume a
fast or slow dispense press the Stop
button. This takes you back to the
Standby mode and does not complete
any more cycles.

FIG. 4-51 RESUME DISPENSE FAST

FIG. 4-52 RESUME DISPENSE SLOW

No Fast Feed Alarm

- - - - - ALARM CONDITION - - - - -

If the Fast Dispense Gate valve or feeder is
not open or on at the time you want to dis-
pense, the NO FAST FEED alarm appears
on the display. (See Fig. 4-53)

FIG. 4-53 NO FAST FEED ALARM

1.

Determine why you do not have Fast
Feed and correct the problem.

2.

Press the Clear button to clear the
alarm. The RESUME DISPENS-
ING? display appears for single speed
or sequential dispensing. (See Fig. 4-
54)

FIG. 4-54 RESUME DISPENSING DISPLAY

3.

Press the Start button to resume dis-
pense. (See fig. 4-55)

4.

In a dual speed simultaneous opera-
tion press the Clear button to clear the
alarm. The RESUME DISPENSING
SLOW display appears. (See Fig. 4-
56)