Command meaning -13, Chapter 7 - operation – Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 111

Advertising
background image

Chapter 7 - Operation

7-13

* Lb or Kg follow data.

In the case where return data is appropriate for the command, an A is
returned by the instrument in the form of:

In the case of an error, the message returned would be:

where 99 is the error number (See Chapter 8,
Troubleshooting, Error Codes and Definitions for a
breakdown of error codes)

NOTE:

The example uses decimal and mnemonic abbreviation format for clarity, however,
the actual data would be in ASCII format.

Command Meaning

1. X

Xmit. When this command is issued without a sub
command, the type of data specified in the format command
will be transmitted to the port issuing the request. When
this command is issued with a subcommand only, the
subcommand data will be transmitted. Only one
subcommand per command is allowed.

2. Transmit data specified in SUB-CMD as follows:

SUB-CMD

Meaning

none

Default to data setup by the format command

A

Accumulated total

G

Gross

N

Net

T

Tare

DE

Deadband

P

Preact

START

CHAR

INSTRUMENT

ADDRESS

CMD

SUB

CMD

7 BYTE

DATA

D-7 . . . D-1

MODE

CR

2 BYTE CHECKSUM

EOT

CHK-1

CHK-2

>

10

X

G

D-7 . . . D-1

Lb or Kg

CRLF

CHK-1

CHK-2

EOT

START

CHAR

INSTRUMENT

ADDRESS

CMD

SUB-CMD

CR

2 BYTE CHECKSUM

EOT

CHK-1

CHK-2

>

10

A

CRLF

CHK-1

CHK-2

EOT

START

CHAR

INSTR.

ADDRESS

CMD

CMD

SUB

CR

2 BYTE CHECKSUM

EOT

CHK-1

CHK-2

>

10

N

9

9

CRLF

CHK-1

CHK-2

EOT