Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 41

Advertising
background image

Chapter 3 - Installation

3-11

J5 Set Point 5

J6 Set Point 6

Pin 1 Lo

Pin 1 Lo

Pin 2 Hi

Pin 2 Hi

J7 Set Point 7

J8 Set Point 8

Pin 1 Lo

Pin 1 Lo

Pin 2 Hi

Pin 2 Hi

Use 22 AWG minimum to 12 AWG maximum wire for J3 through
J8.

NOTE:

See Output Option Board Installation for board installation procedures.

CAUTION

THE CONTACTS ON THE SOLID STATE RELAY WILL OPEN IF A POWER
FAILURE OCCURS. A LIT LED INDICATES THAT THE RELAY HAS BEEN
ACTIVATED.

J3 Serial Port Wiring

The standard serial port J3 is located on the second board inside the
instrument and is configured either as an RS-232 or RS-422/485
port. (See Section 4.1 for port configuration instructions)

The -A model designator in the model number indicates how the
instrument was configured from the factory. (See Table 3-1)

Wire size: 22 AWG minimum to 12 AWG maximum

For -WS wall mount models, route the wiring to J3 through the
upper left side enclosure access hole when facing the front of the
enclosure.

Remote Functions
Wiring

Some functions are level conditions and some are activated by
momentary grounding. Both use the remote functions ground found
on pin 9.

Wire Size:

22 AWG Min. to 12 AWG Max. Shielded

-A1

-A2

-A3

J3

RS-232

RS-422

RS-485

Pins

Signal

Signal

Signal

1

Cts

Tx+

Tr+

2

Rts

Tx-

Tr-

3

Rxd

Rx+

N/C

4

Txd

Rx-

N/C

5

Gnd

Gnd

Gnd

TABLE 3-1: FACTORY CONFIGURATION

Advertising