Set point relay option board installation -d2 -22 – Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 52

Advertising
background image

HI 2151/30WC MANUAL

3-22

Dynamic Data
Exchange (DDE) I/O
Server -B14

RS-232C- Requires an interface cable with a 9 pin or 25 pin serial port
female connector to connect to a computer. Wire the cable to the 5 pin
Phoenix connector J3 located on the rear panel of the weight controller.

Refer to Hardy Instruments optional DDE Installation and Operation
Manual, document number 0596-0221 for more details.

HI 215IT Series
Junction Boxes

Refer to Fig. 3-11 Load Cell/Sensor Connections for specific details.

Wiring to Hardy Instruments Load Points and Load Sensors

TB9

J1 HI 2151/30WC

+EXC

Red

+SEN

Blue

-EXC

Black

-SEN

Brown

Shield
C2+

Grey

C2-

Violet

+SIG

Green

-SIG

White

Set Point Relay Option
Board Installation -D2

The setpoint relay option board must be installed outside of the HI
2151/30WC. (See Fig. 3-18).

Step 1.

Locate a clear, flat mounting area within five feet cable dis-
tance of the HI 2151/30WC.

TB1, 3, 5,7

HI LPH
HI BB01

HI LPS
HI SB01

HI LPD
HI DSB01/2

HI LPT
HI SO1

+ EXC

Green or
Green/Blue

Red

Red

Red

-EXC

Black or
Black/Grey

Black

Black

Black

Shield

Orange or
Yellow

Orange or
Clear

Orange or
Clear

Orange or
Clear

TB2, 4, 6, 8

HI LPH
HI BB01

HI LPS
HI SB01

HI LPD
HI DSBO1/2

HI LPT
HI SO1

C2+

Grey

Grey

Grey

Grey

C2 -

Violet

Violet

Violet

Violet

Sig +

White

Green

Green

Green

Sig -

Red

White

White

White

Advertising