Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 49

Advertising
background image

Chapter 3 - Installation

3-19

FIG. 3-14 BCD QUAD TERMINATION BOARD OPTION

Step 1.

Locate a clear, flat mounting area within five feet of all HI
2151/30WCs.

Step 2.

Use the measurements shown in Figure 3-15 BCD Termina-
tion Board Installation Drill Template Illustration or P/N
0596-0117 drill template to mark five mounting holes. (See
Fig. 3-15)

FIG. 3-15 BCD TERMINATION BOARD INSTALLATION DRILL

TEMPLATE

Step 3.

Drill 3/16-inch holes where marked.

Step 4.

Install five P/N 2815-0053 standoffs in the holes.

Step 5.

Install BCD terminal board on standoffs.

Step 6.

Connect P/N 0509-0389-01 ribbon cables between the BCD
output (instrument option slot 2) of up to four HI 2151/
30WCs and BCD terminal board jacks J1 through J4.Connect
control lines from computer to TB1.

Step 7.

For installations with more than four HI 2151/30WCs, pro-
ceed as follows:

Step 8.

Install a second BCD terminal board within two feet of
installed BCD terminal board. Refer to steps 1 through 7.

Step 9.

Connect P/N 0509-0389-02 ribbon cable from J5 on one BCD
terminal board to J5 on the other BCD terminal board.

Step 10. Connect data/status lines from BCD terminal board to com-

puter. (See Fig. 3-16)

Wire Size: 26 AWG to 20 AWG

4.50"

3.62"

7.25"

Dia .1875

5 places

Advertising